Y2Linux 1.0 Beta 8.29 (Baseline 128)

Debian-based Linux with a fast clickwheel interface for the Innioasis Y2.

Instructions published by the project, shown here word for word.

Y2Linux 1.0 Beta 8.29 (Baseline 128)

Status: PUBLISHED as GitHub release baseline-128 (2026-10-24), not installed on a player before publishing (owner's decision; see Device results). Release 1.0.0-beta.8.29, Reborn 1.0.0-beta.8.29, kernel 6.18.56-y2linux-1.0.0-beta.8.29, update sequence 9300, root 2026.08-platform-v1.169, Linux 4d97301, Reborn e58980c. Built with tools/production/release.py (139 s, resumed workspace, update based on baseline-127): container suite 879 OK; host power/charger modules (test_power, test_charger, test_charge_limits, test_power_policy) 27 OK; all seal checks PASS, no MediaTek firmware in any image. Milestone audit BETA-8.29 in roadmap-gap-audit.

ImageSHA-256
BOOTIMGa95c3528fa072fc6870ab3c4053a8bbe92073abee3d09b87961061371ce37094
Y2ROOTb485165600e9afd82c37d0f6bcb2215f3c8bb5debf3bcdc4e776cbef67c0d452
RECOVERYf88ffa48eda1d84f7694331e78f319a53eedf755c5fa1dcc8eebd2f379d69dcb
Y2DATA (no SSH key)0d6223ef27dea7180b87382aed7a407fef131170be1f831b7e1177a3a0df3d15

Why

A user on Beta 8.28 could not charge at all (reports 09888d70, 8fc8eea6 and ba0bb428, install 047f2c1a, three boots on 2026-10-23). From 0.3 s after every boot the charger driver logged first fault=0x3 sample_error=-61 chr=0x1: the cable was detected, but BAT0 read health "Unspecified failure", status Unknown, 70 mA programmed, and the battery fell 3.70 → 3.64 → 3.61 V over the day.

Cause: the boot log also said mt6323-auxadc: no valid die calibration; temperature unavailable. This player's MT6323 (CID 0x2023, a known revision) does not have its die-temperature calibration-enable fuse set (efuse 0x63a bit 1). y2_pmic_calibrate refused that, so the PMIC die temperature channel returned -ENODATA; the charger reads it in every sample, counted the failure as an ADC/IO fault and inhibited charging before it ever looked at the cable, so the fault never cleared. It is the only one of about 45 installs in the stored reports with die calibration=0.

The stock kernel (mtk_ts_pmic.c, pmic_cali_prepare()) reads the same fuses and, when the bit is clear, uses nominal values: VTS 3698 at 25 °C, slope 0. Setting the fuse is not possible (one-time programmable; the register is a copy reloaded at power-on) and would not help: a clear bit means the calibration words were never written.

What changed since Beta 8.28

ChangeDetailEvidence
A PMIC without its die calibration fuse charges againWith a known CID and the calibration fuse clear, the die sensor uses the stock nominal (VTS 3698, 25 °C, slope 0) instead of returning no data, and reads 10 °C high (owner's choice): nominal reads about 8 °C low through our own player's fuses, so the margin makes the derating steps (60/70/80/90 °C) and both 150 °C stops act early, never late. The PMIC thermal zone is registered in that case tooLinux 1a51503; tests/test_power.py
Calibrated players unchangedThe fused path computes exactly what it did; an unknown CID still returns no datatest_conversion_units_calibration_and_protection (27 °C at the own fuses' reference point, nominal never below own)
Boot logdie calibration=2 for the nominal case and a warning with the CID and both efuse words, so the next report shows the fuse contentsLinux 1a51503

Device results

CheckResult
Owner's playernot installed before publishing: SSH to the player was not available in this session. It has its own calibration fuses, so it would only exercise the unchanged path
Affected playerowed: the reporter (install 047f2c1a) updates by OTA; expected boot lines die calibration=2 and no first fault, BAT0 Charging on a cable

Open

Published by the schulzcode/y2linux project [1] [3]